CQM5 Series Molded Case Circuit Breakers

CQM5 series molded case circuit breaker(herein after referred to as circuit breaker) is suitable for the circuit of AC 50Hz/60Hz, rated voltage to AC690Vand below, rated current16A to 800A,generally used for distribution protection, it can also be used as motor protection. Under normal conditions, the circuit breaker can be used for infrequent circuit conversion and infrequent motor startup.

بولنديون
3P / 4P

التيار المقنن
10A–800A

الجهد المقنن
380/400/415/660/690V AC

Rated ultimate short-circuit breaking capacity:
12/20/36/40/50/55/70/100kA

Rated service short-circuit breaking capacity:
10/15/25/30/36/40/50/70/75kA

قياسي
IEC 60947-2
تخصيص
خدمة شاملة لتصنيع المعدات الأصلية (OEM) والتصنيع حسب الطلب (ODM)

ميزات المنتج

■ Compact design with high breaking capacity (classified into types C, L,H based on performance).

■ Short arc-extinguishing distance and strong anti-vibration performance.

■ Modular structure for easy installation and maintenance.

■ Suitable for both distribution network protection and motor circuit protection.

■ Complies with GB/T 14048.2 and IEC 60947-2 standards.

Operating & Installation Conditions

Ambient temperature: -5℃ to +40℃ (average ≤ +35℃ within 24 hours).

Altitude ≤ 2000 meters above sea level.

Relative humidity ≤ 50% at +40℃.

Must be mounted vertically with tilt tolerance within ±5°.

Pollution degree: 3.

Suitable for protection in distribution and motor circuits.

Accessory List

تعيين النوع

Code Position Code Symbol Meaning & Explanation
CQ Enterprise Code: Zhejiang Chuangqi Electric Co., LTD.
M Product Category: Molded Case Circuit Breaker
5 Design Serial Number
125 Rated Frame Current (A): Options: 63, 100, 125, 250, 400, 630, 800
M Breaking Capacity Class:
• C – Basic Type     • L – Standard Type     • M – Higher Breaking Type     • H – High Breaking Type
Operation Mode:
• (No Code) – Manual Direct Operation     • Z – Rotary Handle Operation     • P – Electric Operation
4 Number of Poles:    • 3 – Three Poles     • 4 – Four Poles
300 Trip Unit & Accessories Code:
• 3 – Electronic Trip (Compound Trip)     • 2 – Magnetic Trip Only (Single Magnetic Trip)
• 00 – No Accessories (Refer to accessory table for specific codes)
Application Type:    • (No Code) – Distribution Protection     • 2 – Motor Protection
B N-Pole Type (For 4P products only, 3P has no code):
• Type A: N-pole is always connected, without overcurrent release.
• Type B: N-pole breaks with other poles, without overcurrent release.
• Type C: N-pole breaks with other poles, with overcurrent release.
• Type D: N-pole is always connected, with overcurrent release.
125A Rated Current: See technical parameter table for available values.
Terminal & Connection Type:
• (No Code) – Front Terminal Connection     • B – Rear Terminal Connection     • C – Plug-in Type

المواصفات الفنية

Model number CQM5-63 CQM5-100
Rated current of frame level Inm(A) 63 100
Rated current In(A),at 40℃ 10, 16, 20, 32, 40, 50, 63 10, 16, 20, 32, 40, 50, 63, 80, 100
Rated operating voltage Ue(V) AC380/400/415V AC380/400/415V
AC660/690V AC660/690V
Rated insulation voltage Ui (V) 1000 1000
Rated impulse withstand voltage Uimp(kV) 8 8
Mechanical life 20000 20000
Electrical life(AC415V) 8000 8000
Trip mechanisms and protection types Thermal-magnetic trip Thermal-magnetic trip
Selectivity category A A
Number of poles 3P 4P 3P 4P
Breaking capacity designation L M C C
Rated ultimate short-circuit breaking capacity (Icu) (kA) AC380/400/415V 36 55 55 40 40
AC660/690V / 12 12 12 12
Rated service short-circuit breaking capacity (Ics) (kA) AC380/400/415V 36 40 40 30 30
AC660/690V / 10 10 10 10
Phase spacing (mm) 25 25
Arc distance (mm) ≤50 ≤50
Operating ambient temp -35℃ to +70℃ -35℃ to +70℃
Accessory Auxiliary contacts
Alarm contacts
Shunt Release
Under-Voltage Release
Motor Operating Mechanism
Manual Handle Assembly
Fixed Type Rear-Mounting Kit
Plug-in Type, Front-of-Panel
Plug-in Type, Rear-of-Panel
Mechanical Interlock
Instantaneous protection Power distribution protection In≤32A:400A; In≥40A:10In In≤32A:400A; In≥40A:10In
Electric motor protection In≤32A:400A; In≥40A:12In In≤32A:400A; In≥40A:12In
Overall dimensions
(mm) (L-W-H)
3 P 130-75-65 130-75-65
4 P 130-100-65 130-100-65

Note:● for optional accessories;”-”for no optional accessories.

Model number CQM5-125 CQM5-250
Rated current of frame level Inm(A) 125 250
Rated current In(A),at 40℃ 10, 16, 20, 32, 40, 50, 63, 80, 100, 125 100, 125, 140, 160, 180, 200, 225, 250
Rated operating voltage Ue(V) AC380/400/415V AC380/400/415V
AC660/690V AC660/690V
Rated insulation voltage Ui (V) 1000 1000
Rated impulse withstand voltage Uimp(kV) 8 8
Mechanical life 20000 20000
Electrical life(AC415V) 8000 8000
Trip mechanisms and protection types Thermal-magnetic trip Thermal-magnetic trip
Selectivity category A A
Number of poles 3P 3P, 4P 4P 3P 3P, 4P 4P
Breaking capacity designation C L M H C L M H
Rated ultimate short-circuit breaking capacity (Icu) (kA) AC380/400/415V 36 50 70 100 36 50 70 100
AC660/690V / / 20 / / / 20 /
Rated service short-circuit breaking capacity (Ics) (kA) AC380/400/415V 25 36 50 70 25 36 50 70
AC660/690V / / 10 / / / 10 /
Phase spacing (mm) 30 35
Arc distance (mm) ≤50 ≤100
Operating ambient temp -35 ℃ to +70℃ -35 ℃ to +70℃
Accessory Auxiliary contacts
Alarm contacts
Shunt Release
Under-Voltage Release
Motor Operating Mechanism
Manual Handle Assembly
Fixed Type Rear-Mounting Kit
Plug-in Type, Front-of-Panel
Plug-in Type, Rear-of-Panel
Mechanical Interlock
Instantaneous protection Power distribution protection In≤40A: 400A; In≥50A: 10In 10In
Electric motor protection In≤40A: 400A; In≥50A: 12In 12In
Overall dimensions
(mm) (L-W-H)
3 P 155-90-75.5 165-105-75
4 P 155-120-87 165-140-100

Note:● for optional accessories;”-”for no optional accessories.

Model number CQM5-400 CQM5-630
Rated current of frame level Inm(A) 400 630
Rated current In(A),at 40℃ 225, 250, 315, 350, 400 400, 500, 630
Rated operating voltage Ue(V) AC380/400/415V AC380/400/415V
AC660/690V AC660/690V
Rated insulation voltage Ui (V) 1000 1000
Rated impulse withstand voltage Uimp(kV) 8 8
Mechanical life 10000 1000
Electrical life(AC415V) 7000 7000
Trip mechanisms and protection types Thermal-magnetic trip Thermal-magnetic trip
Selectivity category A A
Number of poles 3P 4P 3P 3P 4P 3P
Breaking capacity designation C L M / H L M / H
Rated ultimate short-circuit breaking capacity (Icu) (kA) AC380/400/415V 36 50 70 70 100 50 70 70 100
AC660/690V / / 20 20 / / 20 20 /
Rated service short-circuit breaking capacity (Ics) (kA) AC380/400/415V 36 50 70 70 75 50 70 70 75
AC660/690V / / 15 15 / / 15 15 /
Phase spacing (mm) 48 70
Arc distance (mm) ≤100 ≤100
Operating ambient temp -35℃ to +70℃ -35℃ to +70℃
Accessory Auxiliary contacts
Alarm contacts
Shunt Release
Under-Voltage Release
Motor Operating Mechanism
Manual Handle Assembly
Fixed Type Rear-Mounting Kit
Plug-in Type, Front-of-Panel
Plug-in Type, Rear-of-Panel
Mechanical Interlock
Instantaneous protection Power distribution protection 10In 10In
Electric motor protection 12In 12In
Overall dimensions
(mm) (L-W-H)
3 P 275-150-104.5 275-150-104.5
4 P 275-198-104.5 275-198-104.5

Note:● for optional accessories;”-”for no optional accessories.

Model number CQM5-800
Rated current of frame level Inm(A) 800
Rated current In(A),at 40℃ 400, 500, 630, 700, 800
Rated operating voltage Ue(V) AC380/400/415V
AC660/690V
Rated insulation voltage Ui (V) 1000
Rated impulse withstand voltage Uimp(kV) 8
Mechanical life 10000
Electrical life(AC415V) 7000
Trip mechanisms and protection types Thermal-magnetic trip
Selectivity category A
Number of poles 3P 4P 3P
Breaking capacity designation L M / H
Rated ultimate short-circuit breaking capacity (Icu) (kA) AC380/400/415V 50 70 70 100
AC660/690V / 20 20 /
Rated service short-circuit breaking capacity (Ics) (kA) AC380/400/415V 50 70 70 75
AC660/690V / 15 15 /
Phase spacing (mm) 70
Arc distance (mm) ≤100
Operating ambient temp -35℃ to +70℃
Accessory Auxiliary contacts
Alarm contacts
Shunt Release
Under-Voltage Release
Motor Operating Mechanism
Manual Handle Assembly
Fixed Type Rear-Mounting Kit
Plug-in Type, Front-of-Panel
Plug-in Type, Rear-of-Panel
Mechanical Interlock
Instantaneous protection Power distribution protection 10In
Electric motor protection 12In
Overall dimensions
(mm) (L-W-H)
3 P 280-210-112
4 P 280-280-112

Note:● for optional accessories;”-”for no optional accessories.

الأبعاد (مم)

CQM5-63/100

Front Terminal Connection Dimensions (X-X, Y-Y denote center points for 3P breakers)

CQM5-125 (C, L, M, H Types)

Front Terminal Connection Dimensions

(X-X, Y-Y denote center points for 3P breakers)

Model number H(mm) H1 (mm)
CQM5-125C、125L 75.5 101.5
CQM5-125M、125H 87 113

CQM5-250 (C, L, M, H Types)

Front Terminal Connection Dimensions

(X-X, Y-Y denote center points for 3P breakers)

Model number H (mm) H1 (mm)
CQM5-250C、250L 75 103.7
CQM5-250M、250H 100 128.7

CQM5-400 (C, L, M, H Types)

CQM5-630 (C, L, M, H Types)

Front Terminal Connection Dimensions (X-X, Y-Y denote center points for 3P breakers)

CQM5-800 ( L, M, H Types)

Front Terminal Connection Dimensions (X-X, Y-Y denote center points for 3breakers)

Note: Undefined tolerances comply with grade GB/T 1804-80.

لماذا تختار CHAC

مع خبرة تصنيع تزيد عن 30 عامًا، وأكثر من 1100 موظف، وأكثر من 100 مليون عمود
بفضل طاقتها الإنتاجية السنوية ونظام الإنتاج الآلي 90%، توفر شركة CHAC طاقة إنتاجية مستقرة ومعايير صارمة
مراقبة الجودة لعملاء OEM/ODM العالميين. يدعم نظام التصنيع الداخلي الخاص بنا على المدى الطويل
تعاون مع العلامات التجارية الكهربائية والمستوردين والموزعين.


30+

سنوات الخبرة

متخصص في تصنيع المعدات الكهربائية منخفضة الجهد


1100+

الموظفين

فريق محترف يضمن جودة ثابتة والتسليم


١٠٠ مليون+

السعة السنوية للأعمدة

قدرة إنتاجية واسعة النطاق لتلبية الطلب العالمي


90%

الإنتاج الآلي

الأتمتة المتقدمة لتحقيق كفاءة واتساق عاليين

خط التجميع الآلي

خط التجميع الآلي

مختبر اختبار

مختبر اختبار

حقن وختم

حقن وختم

فحص الجودة

فحص الجودة

شهادة IEC
شهادة CE
شهادة CB
شهادة RoHS
شهادة الآيزو 14001

نظام صارم لمراقبة الجودة يضمن أن كل منتج يلبي المعايير العالمية.

ما الذي يمكننا تخصيصه؟

Flexible customization services are available for enclosure dimensions, component configuration,
branding and project requirements.

تصميم حاوية

حَظِيرة
تصميم

أحجام وحاويات مخصصة وهياكل وتفاصيل تركيب.

تصميم حاوية
التكوين الداخلي

داخلي
إعدادات

خيارات مرنة لتخطيط داخلي وترتيب المكونات.

التكوين الداخلي
العلامة التجارية والشعار

العلامة التجارية و
شعار

شعارات العلامة التجارية الخاصة، ولوحات الأسماء، وتحديد الهوية التجارية.

العلامة التجارية والشعار
تصميم عبوات

تعبئة وتغليف
تصميم

علب مخصصة، وملصقات، وأدلة، وحلول تغليف.

تصميم عبوات
التكوين الكهربائي

كهربائي
إعدادات

إعداد كهربائي مخصص بناءً على متطلبات التطبيق.

التكوين الكهربائي
دعم الشهادات

شهادة
دعم

دعم معايير السوق المستهدفة ومتطلبات الامتثال.

دعم الشهادات

تنزيل

ملف PDF

قواطع الدائرة المقولبة من سلسلة CQM5

نظرة عامة كاملة على مكونات كهربائية منخفضة الجهد ومرجع لاختيار المنتج.

تحميل ملف PDF

سوب

هل تحتاج إلى وثائق فنية؟

اتصل بنا للحصول على أوراق البيانات، والشهادات، والرسومات، وإرشادات الاختيار، أو دعم مشاريع OEM/ODM.

اتصل بنا

أسئلة متكررة

س1. هل تدعمون تخصيص المنتجات بناءً على متطلبات التصميم الخاصة بنا؟

أ1: بالتأكيد. نحن متخصصون في التعاون في مجالات تصنيع المعدات الأصلية (OEM) وتصنيع التصميم الأصلي (ODM) في مجال الأجهزة الكهربائية منخفضة الجهد، وقد قدمنا خدمات مخصصة للعديد من الشركات العالمية الشهيرة. نقدم دعمًا لكامل العملية، بما في ذلك تصميم البحث والتطوير، وتعديل المعلمات، واختيار المواد الخاصة، مما يضمن تلبية المنتج لمتطلباتك بالكامل.

س2: ما هي طاقتك الإنتاجية والحد الأدنى لكمية الطلب؟

A2: نحن ندير قاعدة إنتاج مؤتمتة للغاية بإنتاج سنوي يزيد عن 100 مليون عمود للقواطع الكهربائية المصغرة. سياسة الحد الأدنى لكمية الطلب لدينا مرنة. يمكننا توفير طلبات تجريبية تنافسية للكميات الصغيرة وخطط ضمان مخصصة للسعة الإنتاجية.

س 3: ما هي الضمانات المقدمة لجودة المنتج والشهادات؟

ج 3: منتجاتنا الرئيسية حاصلة على شهادات CCC و CE و CB وغيرها، وتُباع في أكثر من 30 دولة ومنطقة حول العالم. وقد أنشأت الشركة «مركز عمليات الجودة» مخصصًا يعمل بالتعاون مع أقسام الأعمال والإنتاج لتطبيق مراقبة الجودة على جميع مراحل العملية، مما يضمن توافق المنتجات مع المعايير الدولية.

س4: هل لديكم القدرة على البحث والتطوير للمنتجات وتحويل الأفكار إلى واقع؟

لدينا فريق بحث وتطوير كامل وورش عمل رقمية، مدعومة بخبرة تخصيص واسعة تخدم العديد من العملاء الدوليين. من اقتراح المفهوم وتطوير العينات إلى الإنتاج الضخم، نقدم دعمًا فنيًا شاملاً لمساعدتك في تحقيق أفكارك.