CQM5 series molded case circuit breaker(herein after referred to as circuit breaker) is suitable for the circuit of AC 50Hz/60Hz, rated voltage to AC690Vand below, rated current16A to 800A,generally used for distribution protection, it can also be used as motor protection. Under normal conditions, the circuit breaker can be used for infrequent circuit conversion and infrequent motor startup.
ميزات المنتج
■ Compact design with high breaking capacity (classified into types C, L,H based on performance).
■ Short arc-extinguishing distance and strong anti-vibration performance.
■ Modular structure for easy installation and maintenance.
■ Suitable for both distribution network protection and motor circuit protection.
■ Complies with GB/T 14048.2 and IEC 60947-2 standards.
Operating & Installation Conditions
Ambient temperature: -5℃ to +40℃ (average ≤ +35℃ within 24 hours).
Altitude ≤ 2000 meters above sea level.
Relative humidity ≤ 50% at +40℃.
Must be mounted vertically with tilt tolerance within ±5°.
Pollution degree: 3.
Suitable for protection in distribution and motor circuits.
Accessory List


تعيين النوع

| Code Position | Code Symbol | Meaning & Explanation |
| ① | CQ | Enterprise Code: Zhejiang Chuangqi Electric Co., LTD. |
| ② | M | Product Category: Molded Case Circuit Breaker |
| ③ | 5 | Design Serial Number |
| ④ | 125 | Rated Frame Current (A): Options: 63, 100, 125, 250, 400, 630, 800 |
| ⑤ | M | Breaking Capacity Class: • C – Basic Type • L – Standard Type • M – Higher Breaking Type • H – High Breaking Type |
| ⑥ | □ | Operation Mode: • (No Code) – Manual Direct Operation • Z – Rotary Handle Operation • P – Electric Operation |
| ⑦ | 4 | Number of Poles: • 3 – Three Poles • 4 – Four Poles |
| ⑧ | 300 | Trip Unit & Accessories Code: • 3 – Electronic Trip (Compound Trip) • 2 – Magnetic Trip Only (Single Magnetic Trip) • 00 – No Accessories (Refer to accessory table for specific codes) |
| ⑨ | □ | Application Type: • (No Code) – Distribution Protection • 2 – Motor Protection |
| ⑩ | B | N-Pole Type (For 4P products only, 3P has no code): • Type A: N-pole is always connected, without overcurrent release. • Type B: N-pole breaks with other poles, without overcurrent release. • Type C: N-pole breaks with other poles, with overcurrent release. • Type D: N-pole is always connected, with overcurrent release. |
| ⑪ | 125A | Rated Current: See technical parameter table for available values. |
| ⑫ | □ | Terminal & Connection Type: • (No Code) – Front Terminal Connection • B – Rear Terminal Connection • C – Plug-in Type |
المواصفات الفنية
| Model number | CQM5-63 | CQM5-100 | |||||
| Rated current of frame level Inm(A) | 63 | 100 | |||||
| Rated current In(A),at 40℃ | 10, 16, 20, 32, 40, 50, 63 | 10, 16, 20, 32, 40, 50, 63, 80, 100 | |||||
| Rated operating voltage Ue(V) | AC380/400/415V | AC380/400/415V | |||||
| AC660/690V | AC660/690V | ||||||
| Rated insulation voltage Ui (V) | 1000 | 1000 | |||||
| Rated impulse withstand voltage Uimp(kV) | 8 | 8 | |||||
| Mechanical life | 20000 | 20000 | |||||
| Electrical life(AC415V) | 8000 | 8000 | |||||
| Trip mechanisms and protection types | Thermal-magnetic trip | Thermal-magnetic trip | |||||
| Selectivity category | A | A | |||||
| Number of poles | 3P | 4P | 3P | 4P | |||
| Breaking capacity designation | L | M | – | C | C | ||
| Rated ultimate short-circuit breaking capacity (Icu) (kA) | AC380/400/415V | 36 | 55 | 55 | 40 | 40 | |
| AC660/690V | / | 12 | 12 | 12 | 12 | ||
| Rated service short-circuit breaking capacity (Ics) (kA) | AC380/400/415V | 36 | 40 | 40 | 30 | 30 | |
| AC660/690V | / | 10 | 10 | 10 | 10 | ||
| Phase spacing (mm) | 25 | 25 | |||||
| Arc distance (mm) | ≤50 | ≤50 | |||||
| Operating ambient temp | -35℃ to +70℃ | -35℃ to +70℃ | |||||
| Accessory | Auxiliary contacts | ● | ● | ● | ● | ● | |
| Alarm contacts | ● | ● | ● | ● | ● | ||
| Shunt Release | ● | ● | ● | ● | ● | ||
| Under-Voltage Release | ● | ● | ● | ● | ● | ||
| Motor Operating Mechanism | ● | ● | ● | ● | ● | ||
| Manual Handle Assembly | ● | ● | ● | ● | ● | ||
| Fixed Type Rear-Mounting Kit | ● | ● | ● | ● | ● | ||
| Plug-in Type, Front-of-Panel | ● | ● | ● | ● | ● | ||
| Plug-in Type, Rear-of-Panel | ● | ● | ● | ● | ● | ||
| Mechanical Interlock | ● | ● | ● | ● | ● | ||
| Instantaneous protection | Power distribution protection | In≤32A:400A; In≥40A:10In | In≤32A:400A; In≥40A:10In | ||||
| Electric motor protection | In≤32A:400A; In≥40A:12In | In≤32A:400A; In≥40A:12In | |||||
| Overall dimensions (mm) (L-W-H) |
![]() |
3 P | 130-75-65 | 130-75-65 | |||
| 4 P | 130-100-65 | 130-100-65 | |||||
Note:● for optional accessories;”-”for no optional accessories.
| Model number | CQM5-125 | CQM5-250 | ||||||||
| Rated current of frame level Inm(A) | 125 | 250 | ||||||||
| Rated current In(A),at 40℃ | 10, 16, 20, 32, 40, 50, 63, 80, 100, 125 | 100, 125, 140, 160, 180, 200, 225, 250 | ||||||||
| Rated operating voltage Ue(V) | AC380/400/415V | AC380/400/415V | ||||||||
| AC660/690V | AC660/690V | |||||||||
| Rated insulation voltage Ui (V) | 1000 | 1000 | ||||||||
| Rated impulse withstand voltage Uimp(kV) | 8 | 8 | ||||||||
| Mechanical life | 20000 | 20000 | ||||||||
| Electrical life(AC415V) | 8000 | 8000 | ||||||||
| Trip mechanisms and protection types | Thermal-magnetic trip | Thermal-magnetic trip | ||||||||
| Selectivity category | A | A | ||||||||
| Number of poles | 3P | 3P, 4P | 4P | 3P | 3P, 4P | 4P | ||||
| Breaking capacity designation | C | L | M | H | C | L | M | H | ||
| Rated ultimate short-circuit breaking capacity (Icu) (kA) | AC380/400/415V | 36 | 50 | 70 | 100 | 36 | 50 | 70 | 100 | |
| AC660/690V | / | / | 20 | / | / | / | 20 | / | ||
| Rated service short-circuit breaking capacity (Ics) (kA) | AC380/400/415V | 25 | 36 | 50 | 70 | 25 | 36 | 50 | 70 | |
| AC660/690V | / | / | 10 | / | / | / | 10 | / | ||
| Phase spacing (mm) | 30 | 35 | ||||||||
| Arc distance (mm) | ≤50 | ≤100 | ||||||||
| Operating ambient temp | -35 ℃ to +70℃ | -35 ℃ to +70℃ | ||||||||
| Accessory | Auxiliary contacts | ● | ● | ● | ● | ● | ● | ● | ● | |
| Alarm contacts | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Shunt Release | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Under-Voltage Release | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Motor Operating Mechanism | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Manual Handle Assembly | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Fixed Type Rear-Mounting Kit | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Plug-in Type, Front-of-Panel | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Plug-in Type, Rear-of-Panel | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Mechanical Interlock | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Instantaneous protection | Power distribution protection | In≤40A: 400A; In≥50A: 10In | 10In | |||||||
| Electric motor protection | In≤40A: 400A; In≥50A: 12In | 12In | ||||||||
| Overall dimensions (mm) (L-W-H) |
![]() |
3 P | 155-90-75.5 | 165-105-75 | ||||||
| 4 P | 155-120-87 | 165-140-100 | ||||||||
Note:● for optional accessories;”-”for no optional accessories.
| Model number | CQM5-400 | CQM5-630 | |||||||||
| Rated current of frame level Inm(A) | 400 | 630 | |||||||||
| Rated current In(A),at 40℃ | 225, 250, 315, 350, 400 | 400, 500, 630 | |||||||||
| Rated operating voltage Ue(V) | AC380/400/415V | AC380/400/415V | |||||||||
| AC660/690V | AC660/690V | ||||||||||
| Rated insulation voltage Ui (V) | 1000 | 1000 | |||||||||
| Rated impulse withstand voltage Uimp(kV) | 8 | 8 | |||||||||
| Mechanical life | 10000 | 1000 | |||||||||
| Electrical life(AC415V) | 7000 | 7000 | |||||||||
| Trip mechanisms and protection types | Thermal-magnetic trip | Thermal-magnetic trip | |||||||||
| Selectivity category | A | A | |||||||||
| Number of poles | 3P | 4P | 3P | 3P | 4P | 3P | |||||
| Breaking capacity designation | C | L | M | / | H | L | M | / | H | ||
| Rated ultimate short-circuit breaking capacity (Icu) (kA) | AC380/400/415V | 36 | 50 | 70 | 70 | 100 | 50 | 70 | 70 | 100 | |
| AC660/690V | / | / | 20 | 20 | / | / | 20 | 20 | / | ||
| Rated service short-circuit breaking capacity (Ics) (kA) | AC380/400/415V | 36 | 50 | 70 | 70 | 75 | 50 | 70 | 70 | 75 | |
| AC660/690V | / | / | 15 | 15 | / | / | 15 | 15 | / | ||
| Phase spacing (mm) | 48 | 70 | |||||||||
| Arc distance (mm) | ≤100 | ≤100 | |||||||||
| Operating ambient temp | -35℃ to +70℃ | -35℃ to +70℃ | |||||||||
| Accessory | Auxiliary contacts | ● | ● | ● | ● | ● | ● | ● | ● | ● | |
| Alarm contacts | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Shunt Release | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Under-Voltage Release | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Motor Operating Mechanism | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Manual Handle Assembly | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Fixed Type Rear-Mounting Kit | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Plug-in Type, Front-of-Panel | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Plug-in Type, Rear-of-Panel | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Mechanical Interlock | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| Instantaneous protection | Power distribution protection | 10In | 10In | ||||||||
| Electric motor protection | 12In | 12In | |||||||||
| Overall dimensions (mm) (L-W-H) |
![]() |
3 P | 275-150-104.5 | 275-150-104.5 | |||||||
| 4 P | 275-198-104.5 | 275-198-104.5 | |||||||||
Note:● for optional accessories;”-”for no optional accessories.
| Model number | CQM5-800 | |||||
| Rated current of frame level Inm(A) | 800 | |||||
| Rated current In(A),at 40℃ | 400, 500, 630, 700, 800 | |||||
| Rated operating voltage Ue(V) | AC380/400/415V | |||||
| AC660/690V | ||||||
| Rated insulation voltage Ui (V) | 1000 | |||||
| Rated impulse withstand voltage Uimp(kV) | 8 | |||||
| Mechanical life | 10000 | |||||
| Electrical life(AC415V) | 7000 | |||||
| Trip mechanisms and protection types | Thermal-magnetic trip | |||||
| Selectivity category | A | |||||
| Number of poles | 3P | 4P | 3P | |||
| Breaking capacity designation | L | M | / | H | ||
| Rated ultimate short-circuit breaking capacity (Icu) (kA) | AC380/400/415V | 50 | 70 | 70 | 100 | |
| AC660/690V | / | 20 | 20 | / | ||
| Rated service short-circuit breaking capacity (Ics) (kA) | AC380/400/415V | 50 | 70 | 70 | 75 | |
| AC660/690V | / | 15 | 15 | / | ||
| Phase spacing (mm) | 70 | |||||
| Arc distance (mm) | ≤100 | |||||
| Operating ambient temp | -35℃ to +70℃ | |||||
| Accessory | Auxiliary contacts | ● | ● | ● | ● | |
| Alarm contacts | ● | ● | ● | ● | ||
| Shunt Release | ● | ● | ● | ● | ||
| Under-Voltage Release | ● | ● | ● | ● | ||
| Motor Operating Mechanism | ● | ● | ● | ● | ||
| Manual Handle Assembly | ● | ● | ● | ● | ||
| Fixed Type Rear-Mounting Kit | ● | ● | ● | ● | ||
| Plug-in Type, Front-of-Panel | ● | ● | ● | ● | ||
| Plug-in Type, Rear-of-Panel | ● | ● | ● | ● | ||
| Mechanical Interlock | ● | ● | ● | ● | ||
| Instantaneous protection | Power distribution protection | 10In | ||||
| Electric motor protection | 12In | |||||
| Overall dimensions (mm) (L-W-H) |
![]() |
3 P | 280-210-112 | |||
| 4 P | 280-280-112 | |||||
Note:● for optional accessories;”-”for no optional accessories.
الأبعاد (مم)
CQM5-63/100
Front Terminal Connection Dimensions (X-X, Y-Y denote center points for 3P breakers)

CQM5-125 (C, L, M, H Types)
Front Terminal Connection Dimensions
(X-X, Y-Y denote center points for 3P breakers)
| Model number | H(mm) | H1 (mm) |
| CQM5-125C、125L | 75.5 | 101.5 |
| CQM5-125M、125H | 87 | 113 |

CQM5-250 (C, L, M, H Types)
Front Terminal Connection Dimensions
(X-X, Y-Y denote center points for 3P breakers)
| Model number | H (mm) | H1 (mm) |
| CQM5-250C、250L | 75 | 103.7 |
| CQM5-250M、250H | 100 | 128.7 |

CQM5-400 (C, L, M, H Types)
CQM5-630 (C, L, M, H Types)
Front Terminal Connection Dimensions (X-X, Y-Y denote center points for 3P breakers)

CQM5-800 ( L, M, H Types)
Front Terminal Connection Dimensions (X-X, Y-Y denote center points for 3breakers)

Note: Undefined tolerances comply with grade GB/T 1804-80.
لماذا تختار CHAC
مع خبرة تصنيع تزيد عن 30 عامًا، وأكثر من 1100 موظف، وأكثر من 100 مليون عمود
بفضل طاقتها الإنتاجية السنوية ونظام الإنتاج الآلي 90%، توفر شركة CHAC طاقة إنتاجية مستقرة ومعايير صارمة
مراقبة الجودة لعملاء OEM/ODM العالميين. يدعم نظام التصنيع الداخلي الخاص بنا على المدى الطويل
تعاون مع العلامات التجارية الكهربائية والمستوردين والموزعين.
30+
سنوات الخبرة
متخصص في تصنيع المعدات الكهربائية منخفضة الجهد
1100+
الموظفين
فريق محترف يضمن جودة ثابتة والتسليم
١٠٠ مليون+
السعة السنوية للأعمدة
قدرة إنتاجية واسعة النطاق لتلبية الطلب العالمي
90%
الإنتاج الآلي
الأتمتة المتقدمة لتحقيق كفاءة واتساق عاليين

خط التجميع الآلي

مختبر اختبار

حقن وختم

فحص الجودة





نظام صارم لمراقبة الجودة يضمن أن كل منتج يلبي المعايير العالمية.
ما الذي يمكننا تخصيصه؟
Flexible customization services are available for enclosure dimensions, component configuration,
branding and project requirements.
حَظِيرة
تصميم
أحجام وحاويات مخصصة وهياكل وتفاصيل تركيب.

داخلي
إعدادات
خيارات مرنة لتخطيط داخلي وترتيب المكونات.

العلامة التجارية و
شعار
شعارات العلامة التجارية الخاصة، ولوحات الأسماء، وتحديد الهوية التجارية.

تعبئة وتغليف
تصميم
علب مخصصة، وملصقات، وأدلة، وحلول تغليف.

كهربائي
إعدادات
إعداد كهربائي مخصص بناءً على متطلبات التطبيق.

شهادة
دعم
دعم معايير السوق المستهدفة ومتطلبات الامتثال.

تنزيل
قواطع الدائرة المقولبة من سلسلة CQM5
نظرة عامة كاملة على مكونات كهربائية منخفضة الجهد ومرجع لاختيار المنتج.
هل تحتاج إلى وثائق فنية؟
اتصل بنا للحصول على أوراق البيانات، والشهادات، والرسومات، وإرشادات الاختيار، أو دعم مشاريع OEM/ODM.
أسئلة متكررة
س1. هل تدعمون تخصيص المنتجات بناءً على متطلبات التصميم الخاصة بنا؟
أ1: بالتأكيد. نحن متخصصون في التعاون في مجالات تصنيع المعدات الأصلية (OEM) وتصنيع التصميم الأصلي (ODM) في مجال الأجهزة الكهربائية منخفضة الجهد، وقد قدمنا خدمات مخصصة للعديد من الشركات العالمية الشهيرة. نقدم دعمًا لكامل العملية، بما في ذلك تصميم البحث والتطوير، وتعديل المعلمات، واختيار المواد الخاصة، مما يضمن تلبية المنتج لمتطلباتك بالكامل.
س2: ما هي طاقتك الإنتاجية والحد الأدنى لكمية الطلب؟
A2: نحن ندير قاعدة إنتاج مؤتمتة للغاية بإنتاج سنوي يزيد عن 100 مليون عمود للقواطع الكهربائية المصغرة. سياسة الحد الأدنى لكمية الطلب لدينا مرنة. يمكننا توفير طلبات تجريبية تنافسية للكميات الصغيرة وخطط ضمان مخصصة للسعة الإنتاجية.
س 3: ما هي الضمانات المقدمة لجودة المنتج والشهادات؟
ج 3: منتجاتنا الرئيسية حاصلة على شهادات CCC و CE و CB وغيرها، وتُباع في أكثر من 30 دولة ومنطقة حول العالم. وقد أنشأت الشركة «مركز عمليات الجودة» مخصصًا يعمل بالتعاون مع أقسام الأعمال والإنتاج لتطبيق مراقبة الجودة على جميع مراحل العملية، مما يضمن توافق المنتجات مع المعايير الدولية.
س4: هل لديكم القدرة على البحث والتطوير للمنتجات وتحويل الأفكار إلى واقع؟
لدينا فريق بحث وتطوير كامل وورش عمل رقمية، مدعومة بخبرة تخصيص واسعة تخدم العديد من العملاء الدوليين. من اقتراح المفهوم وتطوير العينات إلى الإنتاج الضخم، نقدم دعمًا فنيًا شاملاً لمساعدتك في تحقيق أفكارك.