FB Series 50/60Hz Miniature Circuit Breaker

Product overview

FB2-63/FB2H-63

1.Contact point

The use of silver graphite AgC4 can improve the electrical wear performance of the contact and prolong the electrical life.

2.Arc Strip

Through the superposition design of arc starting, the self-excited magnetic field can be effectively enhanced, and the arc starting ability can be improved, and the arc starting effect is good.

3.Terminal block

Adopt large wiring port, and prevent blind insertion of wire design.

4.Clamp

Add a clamp design to the pin, improve insertion and removal performance, and enhance the pin with the contact pressure of the distribution box socket.

5.Arc-extinguishing chamber

Using 13 pieces of arc extinguishing grid design, and combined with the superimposed arc starter, greatly rapid,Improve arc extinguishing ability.

6.Handle and handle cover

Uniform stripe design at the end of the handle prevents fingers from slipping (enhances feel).

FB2L-63/FB2HL-63

1.Compact type

Small size,save space

2.Test button

1P+N and 2P are designed in the same style

3.Terminal block

Adopt small wiring port,and prevent blind insertion of wire design

Technical parameters

Model number FB2-63/FB2H-63
Bracket rating current 63A
Number of poles 1P,2P
Feature Overload and short circuit protection
Rated frequency f(HZ) 50/60Hz
Rated operating voltage Ue(V AC) 240V~
Rated current In(A) 10,16,20,25,32,40,50,63A
Rated insulation voltage Ui(V) 500V
Rated impulse withstand voltage Uimp(kV) 4kV
Rated operating short-circuit breaking capacity (kA) 6kA/7.5kA
Rated limit short-circuit breaking capacity (kA) 6kA/10kA
Current limiting class 3
Instantaneous trip characteristics Electromagnetic type
Trip type C
Electrical service life 4000 times
Service life of machinery 10000 times
Class of protection IP20
Wiring capability (mm²) 1 to 16mm²
Ambient temperature (daily average temperature ℃) 35 ℃ or less
Storage temperature -25℃ to +55℃
Types of climate protection Damp-heat type
Altitude (m) ≤2000m
Relative humidity of air 50%~90%
Pollution level 2
Installation environment /
Installation category Ⅱ or Ⅲ
Installation mode plug-in
Meet the standard IEC 60898-1

 

Model number FB2L-63/FB2HL-63
Bracket rating current 50/63A
Number of poles 1P+N/2P
Feature Overload and short circuit protection
Rated frequency f(HZ) 50/60Hz
Leakage trip mode Electronic formula
Leakage type Type AC
Rated operating voltage Ue(V AC) 240V~
Rated current In(A) 10,16,20,25,32,40,50,63A
Rated insulation voltage Ui(V) 500V
Rated impulse withstand voltage Uimp(kA) 4kV
Rated residual current I△n 30mA
Rated remaining making and breaking capacity I△m 2000A
Rated operating short-circuit breaking capacity (kA) 6kA/7.5kA
Rated limit short-circuit breaking capacity (kA) 6kA/10kA
Current limiting class 3
Instantaneous trip characteristics Electromagnetic type
Trip type C
Electrical service life 4000 times
Service life of machinery 10000 times
Class of protection IP20
Wiring capability (mm²) 1 to 16/25mm²
Ambient temperature (daily average) 35 ℃ or less
Storage temperature -25℃ to +55℃
Types of climate protection Damp-heat type
Altitude (m) ≤2000m
Relative humidity of air 50%~90%
Pollution level 2
Installation environment B
Installation category Ⅱ or Ⅲ
Installation mode plug-in
Meet the standard IEC 61009-1

Dimension

FB2-63

FB2H-63

FB2L-63

FB2HL-63