MCCBs, ACBs and Enclosures for Brands and Panel Builders

OEM/ODM Customization Solutions for Power Distribution Products

CHAC is an MCCB manufacturer serving electrical brands, importers and panel builders. Specify the breaker ratings, trip unit and accessories, then discuss OEM branding or product development. Distribution boxes and junction boxes can be included as separate items, with their own drawings and component requirements.

MCCB Options and Enclosure Requirements

Breaker configuration and enclosure design need different information. Specify the MCCB ratings and accessories on the model list, and show box dimensions, mounting points and component positions on a drawing.

Enclosure Dimensions

Provide the box dimensions, mounting points, cable entries and installation conditions so the proposed enclosure can be reviewed.

Enclosure Design

Component Layout

Show the breaker, terminals and other components on a layout drawing. Confirm operating access, clearances and whether components are supplied fitted or loose.

Internal Configuration

MCCB Brand Identification

Confirm the logo, model designation and nameplate artwork. Product ratings and required markings must remain readable.

Branding and Logo

Packing for Your Project

List unit protection, carton identification, instructions and any project packing-list requirements. Agree on pallet or crate needs for the final order.

Packaging Design

Breaker and Accessory Options

Specify frame, current, voltage, poles, breaking capacity and trip functions. Identify releases, contacts and handles for the exact MCCB series.

Electrical Configuration

Technical Documentation

Request drawings and the reports needed for your market. Confirm which models, ratings and configurations each document covers.

Certification Support
OEM & ODM services

OEM MCCB Branding and Product Development

An OEM MCCB order starts with an existing product specification. Changes to the breaker construction or enclosure layout require drawings and a separate development review.

MCCB units arranged on a production workbench at CHAC Electric
OEM / PRIVATE LABEL

Brand an Existing MCCB Series

Confirm the frame, current rating, trip unit and accessories before reviewing the logo and packaging. Keep the approved sample, identification artwork and specification together as the reference for production.

Send the series, complete configuration, quantities and brand artwork.
CHAC Electric technician operating an MCCB testing station
ODM / DEVELOPMENT REVIEW

Review Breaker or Enclosure Changes

Send the application and proposed drawings for any product change. For an enclosure, include the component list and mounting layout. Agree on feasibility, tooling, sample checks and the work included before production.

Provide the design changes, installation drawing and acceptance requirements.

From MCCB Specification to Production Order

Confirm the breaker configuration and any enclosure work before approving the sample and production order.

01
Define the Order

List the application, breaker ratings and quantities.

02
Agree on Scope

Confirm breaker supply, enclosure work and responsibilities.

03
Review the Design

Check dimensions, trip units, accessories and artwork.

04
Approve the Sample

Approve the configuration, markings and packaging.

05
Confirm Production Requirements

Record inspection checks, approved versions and the delivery milestone.

06
Produce and Deliver

Confirm order lines, packing and delivery terms.

PRODUCT
04

Power Distribution Products for Your Projects

Select breakers and enclosures as separate order items. MCCBs and ACBs need electrical specifications; distribution and junction boxes also need installation drawings and a clear list of included components.

Let’s Plan Your Next Distribution Order

Share your equipment list, project specifications and quantities so CHAC Electric can review the scope and prepare a quotation.

Get Your OEM & ODM Plan
Procurement requirements

MCCB Ratings and Installation Requirements

A current rating alone does not define an MCCB. Include the system voltage, fault level, protection functions and installation details so the proposed model can be checked against the project.

SpecificationWhat to provideWhat to confirm
Frame and rated currentFrame designation and required operating currentFrame rating and rated current are different. Check both on the model sheet.
Voltage and supply systemAC or DC application, operating voltage and polesCheck the model and connection requirements for the actual supply. An AC breaker is not automatically suitable for DC.
Breaking capacityRequired Icu and Ics at the stated operating voltageCompare ratings at the same voltage and applicable standard. Check against the installation fault level.
Trip unitThermal-magnetic or electronic functions and required settingsCheck which functions and adjustment ranges the chosen series offers.
Accessories and dimensionsReleases, contacts, handle, interlock and installation drawingCheck accessory codes and the space needed for mounting. Similar frame labels do not guarantee a fit.
Order and marketQuantity by configuration, destination, branding and document needsKeep the same specification and artwork versions on the quote and purchase order.
Ordering & repeat supply

Agree on MCCB Supply, Approval and Delivery

Separate the breaker, accessory and enclosure requirements on the quotation, then keep the approved details with each order line.

CHAC Electric assembly facilities

Define What Your MCCB Supplier Will Provide

As your MCCB supplier, CHAC can review the breakers and accessories against your required configuration. Identify which accessories should be fitted or supplied loose, and list any enclosures separately. If assembly work is requested, send the layout and component list so its feasibility and cost can be reviewed before it is included in the quotation.

Keep breakers, accessories, enclosures and any assembly work on separate quotation lines.

Testing facilities shown by CHAC Electric

Testing and Approval for Your OEM/ODM Order

CHAC’s OEM/ODM customization quotation for power distribution products includes the costs of product compliance testing and reliability verification within the agreed project scope. Confirm the MCCB frame, current rating, trip unit and accessories, together with any enclosure requirements. Agree on the testing scope and acceptance criteria before sample approval. Keep the approved configuration, drawings and brand artwork as the production reference; later design changes need a further review.

Keep the agreed testing scope, included costs and approved configuration with your OEM/ODM order.

CHAC Electric staff member operating inspection equipment

Identify Each Breaker and Accessory at Delivery

Give each breaker configuration its own order line and use the same references on carton labels and the packing list. Agree on inspection records and shipping documents before dispatch. The receiving team can then check the delivery against the approved configuration; any substitute still needs technical approval.

Use matching order-line references on the purchase order, cartons and receiving checklist.

CHAC Manufacturing for Distribution Products

Your Brand. Our Manufacturing. Since 1995.

CHAC manufactures MCCBs and reviews the selected frame, trip unit and accessories with your sample and inspection requirements. Buyers comparing molded case circuit breaker manufacturers can request the exact model data and proposed inspection scope from CHAC. Production quantities, required records and delivery dates are agreed for the configuration being ordered.

30+

Years of Manufacturing

Low-voltage electrical manufacturing since 1995.

1100+

Employees Across CHAC

Company-wide team supporting manufacturing and engineering.

100M+

Breaker Poles per Year

Company-wide breaker pole capacity; confirm output for your chosen series.

90%

Production Automation

Company-wide automation figure; process coverage varies by product line.

Figures shown are company-wide. Ask us about capacity and automation for the product line you need.

Automated Assembly Line

Automated Assembly Line

Testing Laboratory

Testing Laboratory

Injection & Stamping

Injection & Stamping

Quality Inspection

Quality Inspection

Terminal Electrical Line

Terminal Electrical Line

 Distribution Box Line

Distribution Box Line

MCCB Line

MCCB Line

Industrial Control Line

Industrial Control Line

Procurement FAQ

Power Distribution Procurement Questions

For ACBs and enclosures ordered alongside MCCBs, clarify the configuration, included components and shipping arrangements.

CHAC Electric company building
What ACB details do I need besides the ampere rating?

Specify frame, current, voltage, poles, trip functions and fixed or withdrawable construction. Add the required accessories and any sensor ratings or settings from the project specification. CHAC can then check the available configuration; an ampere rating alone does not define an ACB order.

How do I compare ACB Icu, Ics and Icw ratings?

Icu is ultimate short-circuit breaking capacity; Ics is service short-circuit breaking capacity; Icw is short-time withstand current for a stated duration. Compare values at the same voltage and conditions. Send CHAC the project fault level, coordination requirements and withstand duration to review the proposed ACB.

Does the junction box quote include internal components?

Only the items listed in the agreed supply scope are included. Specify an empty enclosure or list the terminals and other components you need, with dimensions, cable entries and mounting details. Check that CHAC’s quotation and drawing identify the same contents and any assembly work.

How should I compare EXW, FOB and CIF quotations?

Use the same models, quantities, packaging, route and quotation validity. Agree on the Incoterms version and named place or port, then identify handling, freight, insurance, destination charges, duties, taxes and final delivery as applicable. CIF does not include every import or destination charge.

Will ACBs and enclosures need pallets or wooden crates?

Agree on packing according to product size, weight, transport route and handling conditions. Ask CHAC to identify pallet or crate requirements on the offer. If solid wood is used, have the importer or customs adviser confirm the destination’s treatment and marking requirements before shipment.

Which shipping documents can I check before dispatch?

Agree with CHAC on the commercial invoice, packing list, transport document and any required origin or product documents. Check draft descriptions, quantities, weights and consignee details before the relevant documents are finalized. Your customs adviser should confirm the destination-specific requirements.

Procurement resources

Circuit Breaker & Distribution Purchasing Guides

Prepare a clearer equipment specification and compare quotations against the same project requirements.

Project procurement

Choosing Breakers for a Project

Check fault-current data, trip units, panel compatibility and the documents needed for approval before ordering.

Scope & quotation

Planning a Commercial Panel Upgrade

Define capacity, circuit space, shutdown requirements and quotation scope before purchasing distribution equipment.

Discuss Your MCCB Supply & OEM Requirements

Send the MCCB model or required ratings, trip-unit functions, accessories and quantities. For enclosures, attach the dimensions, layout and component list. Identify OEM branding and delivery requirements so the offer can state clearly what is included.

CHAC Product Combination

What to Include in Your Enquiry

Series / frame · Current · Voltage · Poles · Icu / Ics · Trip unit · Accessories · Quantity · Market · Branding

See the specification checklist →

Send Your MCCB Specifications

Contact Form Demo