ExS-T2-DC DC surge protector

The CHAC ExS-T2-DC surge protective device is designed for photovoltaic DC systems, with 2P and 3P configurations selected by operating voltage. A plug-in module, status window and 35mm DIN-rail mounting support installation and maintenance.

Poles:
2P / 3P
Maximum Continuous Operating Voltage (Uc):
2P: 600V / 1000V DC; 3P: 1000V / 1500V DC
Lightning Impulse Current (10/350 μs), Iimp:
Not stated in the current product data
Nominal Discharge Current, In:
20kA
Maximum Discharge Current (8/20 μs), Imax:
40kA
Voltage Protection Level, Up:
≤2.8 / ≤4.0 / ≤5.2kV, depending on configuration
Standard:
IEC/EN 61643-31, Type 2
Customization:
One-Stop OEM/ODM Service

Product Overview

The CHAC ExS-T2-DC photovoltaic DC surge protective device uses plug-in modules and a status window for inspection and maintenance. The range includes 2P and 3P configurations, with the voltage rating selected for the PV circuit and earthing arrangement.

For importers, distributors and equipment manufacturers, CHAC can review the requested configuration against the circuit requirements and destination-market documents. Agree the exact model, drawings and marking requirements before sample approval or a repeat order.

Key Selection Points

  • Maximum continuous voltage: 2P: 600V or 1000V DC; 3P: 1000V or 1500V DC. Match the variant to maximum PV voltage and the required connection arrangement.
  • Discharge-current ratings: In 20kA; Imax 40kA, 8/20µs. These are surge-current ratings, not continuous load current or circuit-breaker interrupting capacity.
  • Connection and mounting: 35mm DIN rail; 1.5–25mm² connection range. Confirm conductor details, earthing layout and the installation instructions.
  • Environment: IP20 device. Use a suitable enclosure and allow access to inspect and replace the correct module.

Typical Applications

Use the ExS-T2-DC as part of a coordinated PV surge-protection design in a suitable enclosure. It addresses transient overvoltage; it does not replace string overcurrent protection, isolation or the wider lightning-protection design.

Applications and Selection Guide

Selection item ExS-T2-DC configuration What to verify
Maximum continuous voltage 2P: 600V or 1000V DC; 3P: 1000V or 1500V DC Match the variant to maximum PV voltage and the required connection arrangement.
Discharge-current ratings In 20kA; Imax 40kA, 8/20µs These are surge-current ratings, not continuous load current or circuit-breaker interrupting capacity.
Connection and mounting 35mm DIN rail; 1.5–25mm² connection range Confirm conductor details, earthing layout and the installation instructions.
Environment IP20 device Use a suitable enclosure and allow access to inspect and replace the correct module.

Use these checks to compare the protection function, configuration and related CHAC products before specifying ExS-T2-DC. Related products are selection alternatives or system components, not automatic replacements.

Coordinate surge protection with the rest of the circuit

Short, correctly routed connections and the required backup protection are part of the installation design.

SelectionConfigurationTechnical Review

Compare CQHS for the required function

The CHAC CQHS PV DC combiner box combines photovoltaic string inputs with a DC isolator for DC-side disconnection. Choose from six input/output configurations to match your PV array layout, and confirm the voltage and current ratings for the selected model.

Related ProductSystem DesignVerify Compatibility

Compare CQHD for the required function

The CHAC CQHD PV DC combiner box combines photovoltaic string inputs with DC circuit-breaker protection. Choose from six input/output configurations to match your PV array layout, and confirm the voltage and current ratings for the selected model.

Related ProductSystem DesignVerify Compatibility

Need Help Specifying ExS-T2-DC?

Send the circuit requirements, selected configuration, destination market and quantity for a model-specific review.

Request a Quote

Choose the voltage and protective arrangement together

Use maximum PV open-circuit voltage under the project temperature conditions when choosing the SPD. Confirm the exact 2P or 3P arrangement and its voltage-protection level against the equipment and earthing system. Do not select a device solely because its maximum voltage is higher.

Coordinate surge protection with the rest of the circuit

Short, correctly routed connections and the required backup protection are part of the installation design. Confirm the backup device for the actual fault level and SPD variant. A Type 2 device must not be presented as a complete solution for every direct-lightning exposure.

How to Specify a ExS-T2-DC Order

Use the configuration details below in the purchase specification. Keep the approved drawing revision and product identification with the order so repeat deliveries can be checked consistently.

Order detail Information to include
Maximum continuous voltage 2P: 600V or 1000V DC; 3P: 1000V or 1500V DC — Match the variant to maximum PV voltage and the required connection arrangement.
Discharge-current ratings In 20kA; Imax 40kA, 8/20µs — These are surge-current ratings, not continuous load current or circuit-breaker interrupting capacity.
Connection and mounting 35mm DIN rail; 1.5–25mm² connection range — Confirm conductor details, earthing layout and the installation instructions.
Environment IP20 device — Use a suitable enclosure and allow access to inspect and replace the correct module.
Project and documents Supply the application, installation conditions and destination-market document requirements.
Quantity and identification State the quantity, sample requirement, packaging language and any proposed branding; confirm feasibility before approval.

Check Installation Fit Before Approval

  • Use the ExS-T2-DC dimension drawing to verify mounting, terminal access, operating clearance and conductor bending space.
  • Confirm conductor preparation, terminal compatibility and tightening instructions for the exact configuration. A conductor reference table does not replace project cable sizing.
  • Review temperature, enclosure conditions and the protective arrangement with the equipment designer. Do not infer compatibility from a similar model name.
  • Have qualified personnel install and verify the equipment using the model instructions and applicable isolation and testing procedures.

Parameter table

Model ExS-T2-DC
Polar Number 2P 2P 3P 3P
Maximum Continuous Operating Voltage Uc (v) DC600 DC1000 DC1000 DC1500
U1ma Pressure-sensitive Voltage (v) 750 1500 750 1100
Maximum Discharge Current Imax (8/20us) (ka) 40
Nominal Discharge Current In (ka) 20
Voltage Protection Level Up (kv) ≤2.8 ≤4.0 ≤5.2
Response Time (ns) ≤25
Maximum Backup Fuse 125AgL/gG
Working Temperature (℃) -40~+70; Relative humidity<95%
Connecting Wire Cross-section (mm2) 1.5-25mm2
Installation Method 35mm standard guide rail
Housing Material Flame retardant material PA6,UL94 V-0
Protection Level IP20
Number Of Ports One port
Unipolar Width (mm) eighteen

Product dimensions

Why Choose CHAC

CHAC Electric supplies electrical protection and control products for importers, distributors and equipment brands. For ExS-T2-DC, agree the configuration, technical documents, approved sample and identification requirements before production. The company facilities shown below provide company context, not a claim that every model uses the same production or test process.

01

CONFIRM THE SPECIFICATION

Agree the ExS-T2-DC configuration, circuit duty and installation requirements.

02

REVIEW THE DOCUMENTS

Confirm model-specific drawings and destination-market requirements.

03

APPROVE THE SAMPLE

Record the accepted configuration and marking requirements.

04

DEFINE ORDER CHECKS

Agree packaging, identification and delivery requirements in the quotation.

CHAC Automated Assembly Line

Automated Assembly Line

CHAC Testing Laboratory

Testing Laboratory

CHAC Injection & Stamping

Injection & Stamping

CHAC Quality Inspection

Quality Inspection

What Can We Customize?

Discuss ExS-T2-DC product identification, packaging and documentation with CHAC. Each proposed change is subject to technical feasibility, marking rules and approval of the exact order; no altered rating or certification is implied.

Logo & Branding

Submit logo artwork and marking requirements for review against the available print area and mandatory product markings.

CHAC ExS-T2-DC product view

Packaging & Manuals

Define carton labels, packaging language, product identification and instruction requirements for the destination market.

CHAC ExS-T2-DC product view

Configuration Selection

Specify ExS-T2-DC with the required maximum continuous voltage, operating conditions and protection duty. Confirm the complete order combination.

CHAC ExS-T2-DC product view

Assembly Requirements

Provide the mounting and connection requirements for review. Changes to the housing, terminals or operating arrangement require engineering approval.

CHAC ExS-T2-DC product view

Market Documentation

Request documents covering the exact ExS-T2-DC model and destination market. A standard reference alone is not evidence of certification.

CHAC ExS-T2-DC product view

Sample Approval

Agree the sample specification, drawing revision and acceptance criteria before confirming a production order.

CHAC ExS-T2-DC product view

Technical Documents and Support

DOC

ExS-T2-DC Technical Documents

Request the ExS-T2-DC datasheet, configuration drawing, installation instructions and available model-specific market documents.Request Datasheet

SUP

Need Technical Documents?

Send the application, electrical requirements, assembly layout and destination market for configuration and document review.Contact Us

ExS-T2-DC Product FAQ

How do I select a surge protector for solar panels?

Check the maximum PV open-circuit voltage, earthing arrangement, lightning-risk assessment and equipment withstand requirements. For ExS-T2-DC, select the appropriate 2P or 3P voltage variant and confirm its protection level and installation requirements.

Can an AC surge protector be used on a DC solar circuit?

Do not substitute an AC SPD based only on a similar voltage marking. Use a device documented for the PV DC circuit. ExS-T2-DC is the CHAC PV DC model; match the exact variant to the installation.

What is the difference between In and Imax on an SPD?

They describe nominal and maximum discharge-current duties under specified surge test conditions. ExS-T2-DC lists In 20kA and Imax 40kA with an 8/20µs waveform. Neither value is a continuous-current rating or an MCCB breaking capacity.

Does a Type 2 SPD protect against every lightning event?

No. Select the SPD class and arrangement from the lightning-risk assessment and coordination design. ExS-T2-DC Type 2 data does not establish a Type 1 impulse-current rating or complete direct-lightning protection.

When should a plug-in SPD module be replaced?

Inspect the status indicator according to the device instructions and replace a failed module with the exact approved type. Confirm voltage and compatibility; matching appearance does not establish interchangeability. Isolate and service the device using the prescribed procedure.

What should I specify when ordering ExS-T2-DC?

Provide maximum PV voltage, earthing arrangement, required poles, protection level, fault/backup-protection requirements and enclosure conditions. Include the desired replacement-module identification, quantity and applicable market documents.