CQDF-32 DC fuse holder

The CHAC CQDF-32 DC fuse holder accepts standard 10 × 38mm fuse links for photovoltaic DC circuits. It is rated at 1000V DC with a maximum current of 32A, and an indicator version is available to suit the specified assembly.

Model:
CQDF-32
Fuse-Link Size:
10 × 38mm
Rated Voltage:
1000V DC
Maximum Rated Current:
32A
Utilization Category:
DC-PV0
Power Loss:
6W
Housing / Indicator:
UL 94 V-0 flame-retardant housing; optional indicator version
Customization:
One-Stop OEM/ODM Service

Product Overview

The CHAC CQDF-32 1000V DC fuse holder accepts 10 × 38mm fuse links for photovoltaic circuits. It has a maximum current rating of 32A and an optional indicator version. The holder and fuse link must be specified together: the base does not determine the required string-fuse current.

For importers, distributors and equipment manufacturers, CHAC can review the requested configuration against the circuit requirements and destination-market documents. Agree the exact model, drawings and marking requirements before sample approval or a repeat order.

Key Selection Points

  • Fuse-link format: 10 × 38mm. Confirm the exact fuse-link series and electrical compatibility, not just its physical fit.
  • Holder ratings: 1000V DC; 32A maximum. Keep the circuit within both ratings and any applicable enclosure-temperature limits.
  • Fuse-current selection: Selected separately for the PV string. Check string current, module maximum series-fuse rating, cable protection and local requirements.
  • Indicator option: With or without indicator. State the required variant on the purchase order and confirm its operating-voltage range.

Typical Applications

Consider the CQDF-32 for PV string-protection assemblies and combiner boxes. Confirm the selected fuse-link category, DC voltage, interruption rating and permissible power dissipation against the module and circuit design.

Applications and Selection Guide

Selection item CQDF-32 configuration What to verify
Fuse-link format 10 × 38mm Confirm the exact fuse-link series and electrical compatibility, not just its physical fit.
Holder ratings 1000V DC; 32A maximum Keep the circuit within both ratings and any applicable enclosure-temperature limits.
Fuse-current selection Selected separately for the PV string Check string current, module maximum series-fuse rating, cable protection and local requirements.
Indicator option With or without indicator State the required variant on the purchase order and confirm its operating-voltage range.

Use these checks to compare the protection function, configuration and related CHAC products before specifying CQDF-32. Related products are selection alternatives or system components, not automatic replacements.

Compare CQHS for the required function

The CHAC CQHS PV DC combiner box combines photovoltaic string inputs with a DC isolator for DC-side disconnection. Choose from six input/output configurations to match your PV array layout, and confirm the voltage and current ratings for the selected model.

Related ProductSystem DesignVerify Compatibility

Compare CQDS-32 for the required function

The CHAC CQDS-32 photovoltaic DC isolation switch provides isolation and infrequent switching between PV modules and inverters. Its non-polar design supports selected DC-PV1/DC-PV2 configurations up to 1200V DC and 32A; follow the wiring arrangement specified for the chosen configuration.

Related ProductSystem DesignVerify Compatibility

Need Help Specifying CQDF-32?

Send the circuit requirements, selected configuration, destination market and quantity for a model-specific review.

Request a Quote

Select the fuse before finalizing the holder order

A 32A base does not mean that every PV string needs a 32A fuse. Start with the module data and string design, then confirm a suitable PV fuse link and its compatibility with the CQDF-32. Include the fuse-link part number in the approved assembly specification.

Plan isolation before fuse replacement

The CQDF-32 data lists DC-PV0. Do not treat the holder as a load-break disconnect or open it under load. Establish a suitable isolation procedure and verify the electrical condition before servicing a fuse; an indicator does not prove absence of voltage.

How to Specify a CQDF-32 Order

Use the configuration details below in the purchase specification. Keep the approved drawing revision and product identification with the order so repeat deliveries can be checked consistently.

Order detail Information to include
Fuse-link format 10 × 38mm — Confirm the exact fuse-link series and electrical compatibility, not just its physical fit.
Holder ratings 1000V DC; 32A maximum — Keep the circuit within both ratings and any applicable enclosure-temperature limits.
Fuse-current selection Selected separately for the PV string — Check string current, module maximum series-fuse rating, cable protection and local requirements.
Indicator option With or without indicator — State the required variant on the purchase order and confirm its operating-voltage range.
Project and documents Supply the application, installation conditions and destination-market document requirements.
Quantity and identification State the quantity, sample requirement, packaging language and any proposed branding; confirm feasibility before approval.

Check Installation Fit Before Approval

  • Use the CQDF-32 dimension drawing to verify mounting, terminal access, operating clearance and conductor bending space.
  • Confirm conductor preparation, terminal compatibility and tightening instructions for the exact configuration. A conductor reference table does not replace project cable sizing.
  • Review temperature, enclosure conditions and the protective arrangement with the equipment designer. Do not infer compatibility from a similar model name.
  • Have qualified personnel install and verify the equipment using the model instructions and applicable isolation and testing procedures.

Parameter table

Model of fuse base Install fuse link size rated voltage Rated current (Max) power loss
CQDF-32 10×38mm 1000V DC 32A 6W

Product dimensions

Why Choose CHAC

CHAC Electric supplies electrical protection and control products for importers, distributors and equipment brands. For CQDF-32, agree the configuration, technical documents, approved sample and identification requirements before production. The company facilities shown below provide company context, not a claim that every model uses the same production or test process.

01

CONFIRM THE SPECIFICATION

Agree the CQDF-32 configuration, circuit duty and installation requirements.

02

REVIEW THE DOCUMENTS

Confirm model-specific drawings and destination-market requirements.

03

APPROVE THE SAMPLE

Record the accepted configuration and marking requirements.

04

DEFINE ORDER CHECKS

Agree packaging, identification and delivery requirements in the quotation.

CHAC Automated Assembly Line

Automated Assembly Line

CHAC Testing Laboratory

Testing Laboratory

CHAC Injection & Stamping

Injection & Stamping

CHAC Quality Inspection

Quality Inspection

What Can We Customize?

Discuss CQDF-32 product identification, packaging and documentation with CHAC. Each proposed change is subject to technical feasibility, marking rules and approval of the exact order; no altered rating or certification is implied.

Logo & Branding

Submit logo artwork and marking requirements for review against the available print area and mandatory product markings.

CHAC CQDF-32 product view

Packaging & Manuals

Define carton labels, packaging language, product identification and instruction requirements for the destination market.

CHAC CQDF-32 product view

Configuration Selection

Specify CQDF-32 with the required fuse-link format, operating conditions and protection duty. Confirm the complete order combination.

CHAC CQDF-32 product view

Assembly Requirements

Provide the mounting and connection requirements for review. Changes to the housing, terminals or operating arrangement require engineering approval.

CHAC CQDF-32 product view

Market Documentation

Request documents covering the exact CQDF-32 model and destination market. A standard reference alone is not evidence of certification.

CHAC CQDF-32 product view

Sample Approval

Agree the sample specification, drawing revision and acceptance criteria before confirming a production order.

CHAC CQDF-32 product view

Technical Documents and Support

DOC

CQDF-32 Technical Documents

Request the CQDF-32 datasheet, configuration drawing, installation instructions and available model-specific market documents.Request Datasheet

SUP

Need Technical Documents?

Send the application, electrical requirements, assembly layout and destination market for configuration and document review.Contact Us

CQDF-32 Product FAQ

What fuse fits a CQDF-32 holder?

The holder accepts the specified 10 × 38mm format. Confirm the exact PV fuse-link series, voltage, current, interruption rating and permitted power dissipation before approving the combination. Physical size alone is not sufficient.

Does a 32A fuse holder require a 32A fuse?

No. The 32A value is the maximum holder current. The selected fuse current depends on the string design, module maximum series-fuse limit, cable protection and installation conditions, and must remain within the holder rating.

Can I open a solar fuse holder under load?

Do not use the CQDF-32 as a load-break switch. Its stated utilization category is DC-PV0. Follow the approved isolation procedure before opening the holder, and use a suitable DC switching device where load disconnection is needed.

Can a fuse holder protect a circuit without a fuse link?

No. The holder supports and connects the fuse link; the correctly selected link provides the specified overcurrent interruption. Define both items in the assembly bill of materials.

Can a 1000V DC fuse holder be used at 1500V DC?

No. Do not exceed the CQDF-32 1000V DC operating rating. Select a holder and fuse link documented for the actual maximum circuit voltage.

What should a CQDF-32 quotation include?

Specify the exact compatible fuse-link type and current, DC operating voltage, indicator requirement, quantity and destination market. Confirm whether the quotation includes holders only or a holder-and-fuse combination.

Specify the Right CQDF-32 Configuration

Send CHAC your required configuration, application, destination market and estimated quantity. We will review the requested specification and provide the relevant technical documents and commercial proposal.

Request a Quote